![]() Longitudinal sections of bolts were prepared from the bolts and examined under microscope. The bolts had a sudden transition in cross section and coarse grinding grooves, both of which are liable to decrease the fatigue strength. Longitudinal sections from four bolts were examined. B Case 2Ī number of cabin bolts from elevators had fractures. The tubes may be annealed to reduce residual stresses. RecommendationĪdmiralty brass tube was recommended because of its good corrosion performance. By EDX-ray analysis, the presence of copper and zinc ions, and some small amounts of chloride, sulfur, silicon and tin were observed. Tube 1 showed blunt transgranular cracking with minimum branching propagating from inside the tube. Tube 1 showed a relatively smooth surface, whereas Tube 2 showed buildup of corrosion products. Examinationīoth tubes showed cracks extending circumferentially above 180☌ on the tension side of the U-bend. Two admiralty brass heat exchanger tubes from a cooler in a refinery unit showed cracks. ![]() Zaki Ahmad, in Principles of Corrosion Engineering and Corrosion Control, 2006 4.9.9 CASE HISTORIES A Case 1 ![]()